Precautions for installation and use of barrier enclosures

2020-09-21 19:18:12
Times

Precautions for installation and use of barrier enclosures

In a general intelligent parking lot management system, barriers are one of the most important parts of the entire system equipment. Parking barriers are widely used in real estate, villas, toll stations, and enterprises and institutions, etc., and are used in smart parking The field management system directly manages the entry and exit of vehicles, so the installation method and use of the barrier are also very important.

There are many techniques that we should pay attention to in the installation of smart parking barriers. At the same time, if the method is not used properly, the equipment will also be prone to failure. Therefore, we pay attention to the installation and use of the barriers in the intelligent parking lot management system, which can extend the service life of the barriers and are not easy to break. Generally speaking, the following points need to be noted:


Precautions for installation and use of barrier enclosures


1. Barriers are generally installed on a level road. If there is a slope, you must pay attention to the installation specifications.

2. After connecting the cable, be sure to perform a careful test. If the test is not working properly, be sure to reinstall it.

3. The installation of the barrier is well coordinated with the ground-sensing coil. The output end of the ground-sensing coil is twisted to the barrier, and the distance is as short as possible. After connecting, seal the nest with dry cement.

4. The ground induction coil should not be damaged during the laying process, and try to avoid joints, otherwise the barriers will not be able to open and drop normally, and failures such as failing to automatically release when vehicles pass.

5. The spring of the barrier system has been adjusted to torque balance according to the length of the bar before leaving the factory. If the barrier is lengthened and cut according to the site conditions, the spring force should be adjusted to the balance, otherwise the motor will overheat and the gearbox will wear excessively. .

When operating the parking lot system, pay attention to vehicles and pedestrians to avoid accidental damage. The barriers are generally equipped with pressure radio waves, which will automatically bounce to prevent the barriers from damaging the vehicles. When there is a power failure, you need to operate to open the door. When the gate pole is in a horizontal state, directly follow the arrow of the clutch and turn the button of the clutch to separate it. The pole can be automatically lifted or manually lifted. When the call comes in, Press the OFF button, the clutch will automatically reset to lower the brake lever to a horizontal state and then resume normal functions.